PolyMount, Kit für Cold Mounting

E1270

Medium für Cold Mounting auf Polyesterbasis, transparent, geringe Viskosität. Wegen Schrumpfung nur für Proben ohne Hohlräume verwenden.
506,40 € 602,62 €

Produktdetails

Beschreibung

Measuring of Components

As a stoichiometer resin: curing agent/hardener ratio is critical, both parts should be weighed to obtain the best mounting result. If it is only possible to measure the amount by volume, use syringes for measuring out quantities of resin and curing agent/hardener. When the syringe is used as a stopper in the cap, it can be used many times without being cleaning.

The minimum mixing amount should be 15 grams of mixed resin and curing agent/hardener, which is approximately the amount required for one 30 mm diameter mount.

Mixing of components
By volume: 50 parts resin/1 parts curing agent

  • Weigh out the correct amount of resin in a mixing cup.
  • Weigh out the corresponding amount of curing agent/hardener into the same mixing cup.
  • Stir thoroughly for 3 minutes without introducing too many air bubbles into the epoxy.
  • Ensure that no air remains trapped within gaps or cavities in the specimen by moving the specimen or by tapping the mounting cup on the table.

Mixed should be used immediately after the 3 minutes described above. If the mixture is not used within short time, excessive heat generation can occur depending on the amount of resin and the room temperature.


The curing time is approximately 8-12 hours at room temperature. This time should decrease with increasing mounting cup size and vice versa. The room temperature should be not be lower than 20°C/68°F as this will result in increased curing time. Insufficiently cured mounts appear softer than correctly cured ones. Such mounts can be post-cured at 40-50°C for 2 hours. Room temperatures higher than 25°C/77°F will result in extreme peak temperatures during curing.


Tip: To avoid a sticky surface of the mount, cover the mounting cup during curing.

Weitere Informationen

Weitere Informationen
Anwendung
REM
Basis
Polyester
Gebotszeichen
Augenschutz benutzen Augenschutz benutzen
Handschutz benutzen Handschutz benutzen
Signalwort
Achtung
Symbol GHS
GHS02 GHS02
GHS07 GHS07
Gefahrenhinweise
H226
H302_H312
H315
H319
Sicherheitshinweise
P210
P241
P261
P280
P321
P303_361_353
P305_351_338
P501
Bestandteile 500 ml Harz, 15 ml Härter
Verpackungseinheit Kit
Versandklasse
Gefahrgut LQ
Hersteller
EMS
SDB (mehrsprachig) E1270-A, E1270-B